Newer
Older
# ESP8266 Lua/NodeMCU module for MH-Z19 CO₂ sensors
[esp8266-nodemcu-mh-z19](https://finalrewind.org/projects/esp8266-nodemcu-mh-z19/)
provides an ESP8266 NodeMCU Lua module (`mh-z19.lua`) as well as MQTT /
HomeAssistant / InfluxDB gateway application example (`init.lua`) for
**MH-Z19** carbon dioxide (CO₂) sensors connected via UART.
## Dependencies
mh-z19.lua has been tested with Lua 5.1 on NodeMCU firmware 3.0.1
(Release 202112300746, integer build). It requires the following modules.
* struct
Most practical applications (such as the example in init.lua) also need the
following modules.
* gpio
* mqtt
* node
* softuart
* tmr
* wifi
## Setup
Connect the MH-Z19 sensor to your ESP8266/NodeMCU board as follows.
* MH-Z19 GND (black wire) → ESP8266/NodeMCU GND
* MH-Z19 Vin (red wire) → NodeMCU 5V
* MH-Z19 Rx (blue wire) → NodeMCU D1 (ESP8266 GPIO5)
* MH-Z19 Tx (green wire) → NodeMCU D2 (ESP8266 GPIO4)
If you use different pins for TXD and RXD, you need to adjust the
softuart.setup call in the examples provided in this repository to reflect
those changes. Keep in mind that some ESP8266 pins must have well-defined logic
levels at boot time and may therefore be unsuitable for MH-Z19 connection.
## Usage
Copy **mh-z19.lua** to your NodeMCU board and set it up as follows.
```lua
mh_z19 = require("mh-z19")
port = softuart.setup(9600, 1, 2)
port:on("data", 9, uart_callback)
function uart_callback(data)
if mh_z19.parse_frame(data) then
-- mh_z19.co2 : CO₂ concentration [ppm]
-- mh_z19.temp : device temperature [°c]
-- mh_z19.abc_ticks : ticks since last Automatic Baseline Correction
-- mh_z19.abc_count : number of Automatic Baseline Corrections performed since power-on
port:write(mh_z19.c_query)
The sensor performs a CO₂ measurement every one to five seconds, depending on hardware revision.
## Application Example
**init.lua** is an example application with HomeAssistant integration.
To use it, you need to create a **config.lua** file with WiFI and MQTT settings:
```lua
station_cfg = {ssid = "...", pwd = "..."}
Optionally, it can also publish readings to InfluxDB.
To do so, configure URL and attribute:
```lua
influx_url = "..."
influx_attr = "..."
```
Readings will be published as `mh_z19[influx_attr] co2_ppm=%d,temperature_celsius=%d,abc_ticks=%d,abc_count=%d`.
So, unless `influx_attr = ''`, it must start with a comma, e.g. `influx_attr = ',device=' .. device_id`.
## Images
![](https://finalrewind.org/projects/esp8266-nodemcu-mh-z19/media/preview.jpg)
![](https://finalrewind.org/projects/esp8266-nodemcu-mh-z19/media/hass.png)
## Resources
Mirrors of this repository are maintained at the following locations:
* [Chaosdorf](https://chaosdorf.de/git/derf/esp8266-nodemcu-mh-z19)
* [git.finalrewind.org](https://git.finalrewind.org/esp8266-nodemcu-mh-z19/)
* [GitHub](https://github.com/derf/esp8266-nodemcu-mh-z19)