# ESP8266 Lua/NodeMCU module for TEMT6000 illuminance sensors
[esp8266-nodemcu-temt6000](https://finalrewind.org/projects/esp8266-nodemcu-temt6000/)
provides an ESP8266 NodeMCU Lua module (`temt6000.lua`) as well as MQTT /
HomeAssistant / InfluxDB integration example (`init.lua`) for **TEMT6000**
illuminance sensors connected via analog output.
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
## Dependencies
temt6000.lua has been tested with Lua 5.1 on NodeMCU firmware 3.0.1 (Release
202112300746, integer build). It requires the following modules.
* adc
Most practical applications (such as the example in init.lua) also need the
following modules.
* gpio
* mqtt
* node
* tmr
* wifi
## Setup
Connect the TEMT6000 sensor to your ESP8266/NodeMCU board as follows.
* TEMT6000 GND → ESP8266/NodeMCU GND
* TEMT6000 VCC → ESP8266/NodeMCU 3V3
* TEMT6000 OUT → ESP8266/NodeMCU A0
Note that the TEMT6000 output will range from 0V to 3V3, whereas ESP8266 A0
only accepts up to 1V. Most NodeMCU boards use a voltage divider to connect
NodeMCU A0 to ESP8266 A0 and are capable of handling up to 3V3 at A0.
## Usage
Copy **temt6000.lua** to your NodeMCU board and set it up as follows.
```lua
temt6000 = require("temt6000")
-- can be called as often as the ADC permits
function some_timer_callback()
local lx = temt6000.read()
if lx ~= nil then
-- lx: estimated illuminance [lx]
-- Note that lx is limited to a usable range of about 20 to 1000 lx.
-- Darkness cannot always be detected reliably,
-- anything brighter than ~1024 lx will be reported as 1024 lx.
else
print("TEMT6000 error")
end
end
```
## Application Example
**init.lua** is an example application with HomeAssistant integration.
To use it, you need to create a **config.lua** file with WiFI and MQTT settings:
```lua
station_cfg = {ssid = "...", pwd = "..."}
mqtt_host = "..."
```
Optionally, it can also publish readings to InfluxDB.
To do so, configure URL and attribute:
```lua
influx_url = "..."
influx_attr = "..."
```
Readings will be published as `temt6000[influx_attr] illuminance_lx=%d,adc_counts=%d`.
So, unless `influx_attr = ''`, it must start with a comma, e.g. `influx_attr = ',device=' .. device_id`.