Original line number Diff line number Diff line
# kaxxxxp-viewer - Data Logger and Viewer for KAxxxxP power supplies

**kaxxxxp-viewer** acquires and visualizes voltage and current data from
KAxxxxP power supplies. These PSUs are equipped with a USB port, which can
be used both for remote control and data acquisition using a serial protocol.
KAxxxxP power supplies. These are sold under brand names such as Korad or RND
Lab and equipped with a USB serial port, allowing them to be used as simple,
low-resolution measurement devices. See the [sigrok
wiki](https://sigrok.org/wiki/Korad_KAxxxxP_series) for details.

It has been successfully used with "RND 320-KA3005P" (single-channel) and "RND
320-KA3305P" (dual-channel) supplies. Observed attributes:

* Time resolution: **a few Hz**
* Voltage range: 0 .. 30 V
* Voltage resolution: 10 mV
* Current range: 0 .. 5 A
* Current resolution: 1 mA

Voltage and current range depend on the device, the resolutions are probably
identical.

**Warning:** In addition to reading voltage and current values, the serial
interface also supports *setting* them. This is not supported by
kaxxxxp-viewer. However, be warned that communication errors or bugs may cause
the power supply to receive a write command with an arbitrary voltage or
current value, which may result in damaged equipment, fire, or other harm. By
using this software, you acknowledge that you are aware of these risks.

See `bin/kaxxxxp-viewer --help` for usage details.

+4 −1
Original line number Diff line number Diff line
@@ -9,7 +9,8 @@

DESCRIPTION

kaxxxxp-viewer logs voltage and current readings provided by a KAxxxxP power supply.
kaxxxxp-viewer logs voltage and current readings provided by a KAxxxxP power supply
with serial/USB interface, sold under brands such as Korad or RND Lab.
Measurements can be taken directly (by specifying <measurement duration> in seconds)
or loaded from a logfile using --load <file>. Data can be plotted or aggregated on stdout.

@@ -131,6 +132,8 @@ class KA320:
            return self.reader.get_expected_line()
        return self.reader.get_line()

    # See <https://sigrok.org/wiki/Korad_KAxxxxP_series> for supported commands

    def connect(self):
        return self.rw(b"*IDN?", 16)